BRK 790MBX Mains Powered Hard Wired Heat Alarm with 9V Battery Back Up by BRK

£24.65 £19.45
In Stock Add to Cart
Usually dispatched within 1-2 business days

Description

Carbon Monoxide Alarms are happy to present the fantastic BRK 790MBX Mains Powered Hard Wired Heat Alarm with 9V Battery Back Up.

With so many on offer today, it is wise to have a brand you can recognise. The BRK 790MBX Mains Powered Hard Wired Heat Alarm with 9V Battery Back Up is certainly that and will be a perfect buy.

For this great price, the BRK 790MBX Mains Powered Hard Wired Heat Alarm with 9V Battery Back Up comes widely respected and is a popular choice with lots of people. BRK have provided some nice touches and this means great value for money.

Manufacturer Description

Mains powered hard wired heat alarm with 9V alkaline battery back up and a PUSH-FIT docking base system; designed to ensure quick and easy installation of base unit to the mains feed supply at installation stage (1st fix) and for quick and easy connection of alarm to base unit (2nd fix). The PUSH-FIT base provides spacious room for wiring in premises such as flats where concrete ceilings can be problematic. Top and side entries accommodate for either cable or mini trunking installations. These alarms can be installed, along with linked smoke alarms, to provide a fire detection system to comply with British Standard BS 5839: Pt.6 Grade D "System incorporating one or more interlinked mains powered smoke alarms (and heat alarms if required), each with an integral stand-by supply. The interlink can be hardwired or radio-interlinked". Heat alarm are normally used in locations where the use of a smoke alarm would give rise to nuisance alarms, e.g. Kitchen, Garage, Boiler Rooms, Lofts etc. Heat Alarms should not be used as the sole fire protection method and should only be used in conjunction with Smoke Alarms. Multi-alarm interlink:- When more than one alarm is installed within the same building these should be connected together so that if one alarm is activated , all alarms sound. The normal wiring method for these alarms is 6242Y 1 or 1.5mm (twin & earth) from the power supply, which can be either a dedicated circuit at the consumer unit or a local normally used lighting circuit, to the first alarm position then 6243Y 1 or 1.5mm (3 core & earth) from the first alarm to the second alarm and so on. The maximum circuit length is 250 metres. Alternatively you can use the DS700RF Wireless Interlink Base to replace the interlink. Please note that when using interlink bases a permanent power supply is still required to each alarm position (using 6242Y 1 or 1.5mm twin & earth cable). This model replaces the BRK 680MBX which is now out of production.

Features

230V hard wired mains powered heat detector / alarm. 9V alkaline battery back-up (included) PUSH-FIT docking base. No separate pattress plate required. Test and silence button Advanced Class A2 thermistor sensing technology. Activates in range of +54°C to +70°C Multi-alarm interlink (up to 12 smoke and heat units from list below). Compatible with DS700RF base 85db alarm. BS EN14604: 2005 standard. CE mark